Compu-Kool

Split System

2–5 Ton capacity

Air, Water, Chilled Water and Glycol

All computers are highly sensitive to their environment. To function efficiently, they require specific temperature, humidity, and filtration conditions. Failure to meet these specified conditions can result in distorted or lost data and even complete shutdown of computer services.

Compu-Aire understands the special environmental control needs of computer, electronic and telecommunications rooms.

 

Fully Insulated Cabinet the Compu-Aire Compu-Kool III cabinet is constructed of 14 gauge heliarc welded tubular steel for strength and protection. Front access is made easy for servicing via well insulated access panels. A 1” thick, 1.5lb density insulation is utilized. The cabinet has decorative front and side panels, which can be color-coordinated with the décor of the computer room.

Compu-Aire is concerned about energy conservation, which is why the Compu-Aire Compu-Kool III standard reheat is provided in two stages. Each element is finned tubular type, with a low watt density design for extended life.

 

Each Compu-Aire Compu-Kool III is provided with a pre-piped and pre-wired electronic electrode self-generating steam type humidifier. Completely maintenance free, the humidifier is equipped with a disposable cylinder. The vapor produced is piped directly into the supply air for efficient moisture introduction.

 

Easy Access To Filters the Compu-Aire Compu-Kool III has standard 2” thick pleated media high efficiency MERV 8 filters which are serviceable from the front of the unit for upflow units and from the top for downflow units.

The Compu-Kool III shall be provided with state of art user interface, Advanced Microprocessor-System 2200 Plus With Graphical Display  featuring 5.7” touch screen display with 1/4  VGA resolution, and a 32-bit microprocessor that provide  up to 320X240 pixels in size and up to 256 colors, various animated icons, non-proportional fonts in Unicode format and trend graphs. Touch screen functions makes it easier for the user to understand and set the control parameters on System 2200+ series controller.

 

Compu-Kool III Split System features a pre-charged evaporator coil and expansion valve in the computer room unit, with the scroll compressor, and the condensing equipment located in 4 different types of condensing units Air Cooled Condenser (ACC), Propeller fan type condensing unit (PFCU), Air Cooled Condensing Unit (ACCU), Centrifugal fan type condensing unit (CFCU), Water cooled condensing unit (WCCU) and WCCU/DFC water cooled condensing unit with remote dry fluid cooler and pump that can easily adapt to the customer needs.

 

The Compu-Kool Coil is provided with high efficiency fins and a larger coil face area. The coil has been designed to provide the maximum sensible heat ratio required by computer rooms and, at the same time, minimizing energy used in air circulation. The coil is split into two stages. The flow of refrigerant is controlled by an externally equalized valve.

 

The stainless steel condensate drain pan is provided under the coil with two drains.

Options Available:

 

Upflow

 

Air Plenum

 

HEPA Filters

 

Floor Stand

 

Plug Fan with EC Motor

 

Smoke Detector

 

Leak Detection Sensor

 

Condensate Pump

 

Refrigerants R-407C & R-410A

 

Intelligent Microprocessor

 

Communication Cards:

RS-485, pCO Web and BACnet

Brochure

Installation Operational Manual (IOM)