Compu-Kool

All computers are highly sensitive to their environment. To function efficiently, they require specific temperature, humidity, and filtration conditions. Failure to meet these specified conditions can result in distorted or lost data and even complete shutdown of computer services.

Compu-Aire understands the special environmental control needs of computer, electronic and telecommunications rooms.

 

Each Compu-Aire Compu-Kool is provided with a pre-piped and pre-wired electronic electrode self-generating steam type humidifier. Completely maintenance free, the humidifier is equipped with a disposable cylinder. The vapor produced is piped directly into the supply air for efficient moisture introduction.

Flexible Configurations.

Front, Left or Right Side Maintenance Access

Easy Filter Access

 

The Compu-Aire Compu-Kool III has standard 2” MERV 8 thick pleated media high efficiency filters which are serviceable from the front of the unit for upflow units and from the top for downflow units.

Fully Insulated Cabinet

The Compu-Aire Compu-Kool III cabinet is con- structed of 14 gauge heliarc welded tubular steel for strength and protection. Front access is made easy for servicing via well insulated access panels. A 1” thick, 1.5lb density insulation is utilized. The cabinet has decorative front and side panels, which can be color-coordinated with the décor of the computer room.

 Up to 10 Ton

Available Capacities:

The Compu-Kool Coil is provided with high efficiency fins and a larger coil face area. The coil has been designed to provide the maximum sensible heat ratio required by computer rooms and, at the same time, minimizing energy used in air circulation. The coil is split into two stages. The flow of refrigerant is controlled by an externally equalized valve.

 

Compu-Kool III Split System features a pre-charged evaporator coil and expansion valve in the computer room unit, with the scroll compressor, and the condensing equipment located in 4 different types of condensing units Air Cooled Condenser (ACC), Propeller fan type condensing unit (PFCU), Air Cooled Condensing Unit (ACCU), Centrifugal fan type condensing unit (CFCU), Water cooled condensing unit (WCCU) and WCCU/DFC water cooled condensing unit with remote dry fluid cooler and pump that can easily adapt to the customer needs.

Designed for

Refrigerant R-410A

Advanced Microprocessor

The Compu-Kool shall be provided with state of art user interface, Advanced Microprocessor-System 2500 Plus With Graphical Display  featuring 7” touch screen display with a 32-bit microprocessor that provide  up to 800X420 pixels in size and up to 64 K colors, various animated icons, non-proportional fonts in Unicode format and trend graphs. Touch screen functions makes it easier for the user to understand and set the control parameters on System 2500  series controller.

Available Options

Communication Cards:

RS-485, pCO Web and BACnet

 

Smoke Detector

 

Leak Detection Sensor

 

Condensate Pump

 

Multiple Sensors

Stand Alone Networks

Local and remote monitoring can be achieved with our advanced microprocessor controller. Based systems are used to provide standalone supervision and control over a pLAN network giving the flexibility of a BMS system at the fraction of the cost.

Air Cooled Condenser

Compu-Kool Split System features a pre-charged evaporator coil and expansion valve in the computer room unit, with the scroll compressor, and the condensing equipment located in 4 different types of condensing units Air Cooled Condenser (ACC), Propeller fan type condensing unit (PFCU), Air Cooled Condensing Unit (ACCU), Centrifugal fan type condensing unit (CFCU), Water cooled condensing unit (WCCU) and WCCU/DFC water cooled condensing unit with remote dry fluid cooler and pump that can easily adapt to the customer needs.

 Vertical Discharge

Protective Coatings Available

© Compu-Aire  2019. All Rights Reserved.